Technical Library

Standards

  European Standards

Systems

BSEN12845: Automatic Sprinkler System

BSEN12845 Part 2: ESFR and CMSA sprinkler systems

BSEN12845 Part 3: Guidance for earthquake bracing

BSEN16925: Automatic residential sprinkler systems 

BSEN14972 Part 1: Design Codes for Watermist Systems

CEN/TS14816: Design Codes for waterspray Systems

BSEN12101 Part 6: Smoke & heat control systems

BSEN12416 Part 2: Dry powder firefighting systems

BSEN15004 Part 1: Gaseous systems general

BSEN15004 Part 5: Gaseous systems HFC227ea

BSEN15004 Part 7: Gaseous systems IG-01 (Argon)

BSEN15004 Part 9: Gaseous systems IG-55 (Argonite)

BSEN15004 Part 10: Gaseous systems IG-541 (Inergen)

BSISO15686 Part 1: Building service life planning - general

BSISO15686 Part 2: Building service life planning - procedures

BSISO15686 Part 3: Building service life planning - performance

BSEN13501 Part 1: Fire classification of building products

BSEN13501 Part 2: Fire classification of building products

BSEN13501 Part 3: Fire classification of building products

BSEN13501 Part 4: Fire classification of building products

BSEN13501 Part 5: Fire classification of building products

Euroclass fire products

Fire Equipment

BSEN3 Part 7: Portable fire extinguishers

BSEN3 Part 10: Portable fire extinguishers conformity

BSEN54 Part 1: Fire alarm systems introduction

BSEN54 Part 2: Fire alarm control and indicating equipment

BSEN54 Part 3: Fire alarm sounder devices

BSEN54 Part 4: Fire alarm power supply equipment

BSEN54 Part 5: Fire alarm heat detectors

BSEN54 Part 7: Fire alarm smoke detectors

BSEN54 Part 11: Fire alarm manual call points

BSEN54 Part 20: Fire alarm aspirating smoke detectors

BSEN671 Part 1: Hosereels with semi-rigid hose

BSEN671 Part 2: Hose systems with lay flat hose

BSEN671 Part 3: Maintenance of hose reels

BSEN14339: Underground fire hydrants

BSEN12259 Part 1: Components for systems - sprinklers

BSEN12259 Part 2: Components for systems - wet alarm valves

BSEN12259 Part 4: Components for systems - water motor alarms

BSEN12259 Part 12: Components for systems - pumps

BSEN12259 Part 14: Components for systems - residential spks

BSEN17451: Automatic sprinkler system pump sets

BSEN13280: GRP cold water tanks

Equipment Fire Fighting Foams and components

BSEN1568 Part 1: Foam concentrates medium expansion

BSEN1568 Part 2: Foam concentrates high expansion

BSEN1568 Part 3: Foam concentrates low expansion

BSEN1568 Part 4: Foam concentrates low expansion

BSEN13565 Part 1: Foam system components

Pipe, Fittings & Valves

BSEN558 Part 1: PN designated valve dimensions

BSEN558 Part 2: Class designated valve dimensions

BSEN593: Industrial metallic butterfly valves

BSEN1171: Industrial cast iron valves

BSEN12627: Butt welded steel valves

BSEN1092 Part 1: PN designated flanges and joints

BSEN1515 Part 1: Flange bolting

BSEN1515 Part 2: Classification of bolt material

BSEN10216 Part 1: Seamless non-alloy steel tubes

BSEN10216 Part 2: Seamless non-alloy and alloy steel tubes

BSEN10216 Part 5: 4 Seamless stainless-steel tubes

BSEN10217 Part 1: Welded non-alloy steel tubes

BSEN10226 Part 1: Pipe taper and parallel threads

BSEN10255: Non-alloy steel tubes for welding and threading

BSEN10241: Steel threaded pipe fittings

BSEN10253 Part 1: Butt welded carbon steel pipe fittings

BSEN10253 Part 2: Butt welded non-alloy steel pipe fittings

BSEN12201 Part 1: Polyethylene pipe systems - general

BSEN12201 Part 2: Polyethylene pipe systems - pipes

BSEN12201 Part 3: Polyethylene pipe systems - fittings

WIS 4-32-14 Polyethylene pipes

WIS 4-32-15 Polyethylene fittings

Other

BSEN287 Part 1: Qualification test of steel fusion welders

BSEN60529: Protection provided by enclosures (IP code)

BSENISO1461: Hot dipped galvanise coatings

BSENISO15614 Part 1: Arc and gas welding off site

  British Standards

Systems & Equipment

BS3251: Indicator plates for fire hydrants

BS5041 Part 1: Landing valves for wet risers

BS5041 Part 2: Landing valves for dry risers

BS5041 Part 3: Breeching valves for dry risers

BS5041 Part 4: Boxes for landing valves for dry risers

BS5306 Part 0: Selection of installed systems

BS5306 Part 1: Hosereels and Foam Inlets

BS5306 Part 3: Portable fire extinguishers

BS5306 Part 4: Carbon dioxide systems

BS5306 Part 6.1: Low expansion foam systems

BS5306 Part 6.2: Medium & High Expansion Foam Systems

BS5306 Part 8: Portable fire extinguishers

BS5839 Part 1: Fire detection and fire alarm systems

BS5839 Part 3: Release mechanisms for fire protection equipment

BS5839 Part 6: Fire detection and fire alarm systems in dwellings

BS5839 Part 8: Voice alarm systems

BS5839 Part 9: Emergency voice communications systems

BS7273 Part 1: Electrical actuation of gaseous systems

BS7273 Part 2: Mechanical actuation of gaseous systems

BS7273 Part 3: Electrical actuation of sprinkler systems

BS7273 Part 4: Actuation of release mechanisms for doors

BS7273 Part 5: Electrical actuation of watermist systems

BS7543: Durability of building elements, products & components 

BS7974: Fire safety engineering in the design of buildings

BS8210: Facilities maintenance management

BS9251: Residential Sprinkler Systems

BS9990: Hydrants, Wet and Dry Risers

BS9991: Design, Management and Use of Residential Buildings

BS9996: Commissioning of Integrated Fire Safety Systems

BS9999: Design, Management and Use of Buildings

Pipe Supports

BS3974 Part 1: Pipe Hangers, Sliders and roller type supports
BS3974 Part 2: Pipe clamps, cantilevers and attachment to beams

BS3974 Part 3: Pipe Hangers, LB and HT type supports

BS3692: Metric Hexagonal Bolts, Screws and nuts
BS4190: Metric Black Hexagonal Bolts, Screws and nuts

Pipe Fittings & Valves

BS143&1256: Threaded pipe fittings in malleable cat iron

BS2080: Dimensions of valves
BS3643 Part 1: Metric screw threads
BS3643 Part 2: Metric screw threads
BS3799: Steel screwed and socket weld fittings
BS6362: Stainless steel pipe and fittings threads

Identification & Signage

BS1635: Graphic symbols for fire protection drawings
BS1710: Identification of pipelines and services
BS4800: Paint colours for building purposes
BS5499 Part 1: Fire Safety Signs - Shapes, colours and layout
BS5499 Part 4: Fire Safety Signs - Escape route signage
BS5499 Part 5: Fire Safety Signs - With specific safety meaning
BS5499 Part 10: Fire Safety Signs - Use of safety signs
BS3251: Indicator plates for fire hydrants

Fire Safety
BS9792 Fire risk assessment: Housing
PAS 79 Part 1: Fire risk assessment: Non-housing
PAS 9980: External wall assessments

  FM Data Sheets

Construction

1-3: High-Rise Buildings

1-6: Cooling Towers

1-12: Ceilings and Concealed Spaces

1-13: Chimneys

1-16: Fire Protection for Buildings Over Highways

1-19: Fire Walls, Subdivisions and Draft Curtains

1-20: Protection Against Exterior Fire Exposure

1-23: Protection of Openings in Fire Subdivisions

1-25: Process Tanks and Silos

1-45: Air Conditioning and Ventilating Systems

1-53: Anechoic Chambers

1-57: Plastics in Construction

1-60: Asphalt-Coated/Protected Metal Buildings

1-61: Impregnated Fire-Retardant Lumber

Sprinklers

2-0: Installation Guidelines for Automatic Sprinkler 

2-1: Prevention of Internal Corrosion in Automatic Sprinkler Systems

2-5: Installation Rules for Sprinkler in residential occupancies

2-8: Earthquake Protection for Water-Based Fire Protection Systems

2-10R: Dry Pipe, Deluge, Pre-action Valves and Accessories

2-58: Indicator Post Valves - Turns to Open

2-69: Unlisted Automatic Sprinklers

2-74: Identification of FMRC-Approved Plated Sprinklers

2-81: Fire Protection System Inspection, Testing and Maintenance

2-89: Pipe Friction Loss Tables

Water Supply

3-0: Hydraulics of Fire Protection Systems

3-1: Tanks and Reservoirs for Fire and Public Services

3-2: Water Tanks for Fire Protection

3-3: Cross Connections

3-4: Embankment-Supported Fabric Tanks

3-6: Lined Earth Reservoirs for Fire Protection

3-7: Stationary Pumps for Fire Protection

3-10: Installation/Maintenance of Fire Service Mains

3-11: Pressure Reducing Valves for Fire Protection Service

3-26: Water Demand for Non-storage Sprinklered Properties

Extinguishing Equipment

4-0: Special Protection Systems

4-1N: Fixed Water Spray Systems for Fire Protection

4-2: Water Mist Systems

4-3N: Medium and High Expansion Foam Systems

4-4N: Standpipe and Hose Systems

4-5: Portable Extinguishers

4-7N: Low Expansion Foam Systems

4-8N: Halon 1301 Extinguishing Systems

4-9: Clean Agent Fire Extinguishing Systems

4-10: Dry Chemical Processing Systems

4-11N: Carbon Dioxide Extinguishing Systems (NFPA)

4-12: Foam-Water Sprinkler Systems

Electrical

5-4: Transformers

5-14: Telecommunications

5-16: Arc Furnace Transformer Installations

5-31: Cables and Bus Bars

5-32: Electronic Data Processing Systems

5-40: Fire Alarm Systems

5-48: Automatic Fire Detection

Heating Equipment

6-9: Industrial Ovens and Dryers

Hazards

7-0: Causes and Effects of Fires and Explosions

7-10: Wood Processing and Woodworking Facilities

7-11: Belt Conveyors

7-14: Protection for Flammable Liquid & Liquefied Gas

7-17: Explosion Suppression Systems

7-23: Data on general classes of chemicals

7-27: Spray Application of Flammable and Combustible Materials

7-29: Flammable Liquid Storage in Portable Containers

7-31: Storage of Aerosol Products

7-32: Flammable Liquid Operations

7-78: Industrial Exhaust Systems

7-79: Fire Protection for Gas Turbine Installations

7-90: Housing and Recreational Vehicle Manufacturing Plants

7-93N: Aircraft Hangers (NFPA)

7-101: Fire Protection for Turbines and Generators

Storage

8-1: Commodity Classification

8-3: Rubber Tire Storage

8-9: Storage of Class 1, 2, 3, 4 and Plastic Commodities

8-18: Storage of Hanging Garments

8-21: Roll Paper Storage

8-22: Storage of Baled Wastepaper

8-23: Rolled Nonwoven Fabric Storage

8-24: Idle Pallet Storage

8-29: Refrigerated Storage

8-30: Storage of Carpets

8-33: Carousel Storage and Retrieval Systems

8-34: Protection for Automatic Storage and Retrieval Systems

  NFPA Standards

NFPA 11: Standard for Low, Med and High Expansion Foam Systems

NFPA 12: Standard for Carbon Dioxide Extinguishing Systems

NFPA 13: Standard for the Installation of Sprinkler Systems

NFPA 13D: Standard for the Installation of Domestic Sprinklers

NFPA 13R: Standard for the Installation of Residential Sprinklers

NFPA 14: Standard for Standpipe and Hose Systems

NFPA 15: Standard for Water Spray Systems

NFPA 16: Standard for Foam Enhanced Sprinkler Systems

NFPA 20: Stationary Pumps for Fire Protection

NFPA 22: Water Tanks for Private Fire Protection

NFPA 24: Private Fire Service Mains and their Appurtenances

NFPA 25: Maintenance of Water Based Fire Protection Systems

NFPA 30: Flammable and Combustible Liquids Code

NFPA 72: National Fire Alarm Code

NFPA 101: Life Safety Code

NFPA 214: Water Cooling Towers Fire Protection Systems

NFPA 409: Aircraft Hanger Fire Protection Systems

NFPA 750: Standard for Water Mist Fire Protection Systems

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems

  International & Sector Standards

Australian Codes

AS2118.1:2006 Automatic Fire Sprinkler Systems

Peoples Republic of China Codes

GB 50084-2001: Code of design for sprinkler systems

Fire Offices Committee

Installation of External Drenchers

Tentative Rules for water spray systems

Matther & Platt

Fire Protection of Tanker Loading and Off-Loading Areas

American Petroleum Institute

API-570: Piping inspection code

API-1574: Four inch hydrant systems

API-2001: Fire protection in refineries

API-2021: Management of atmospheric storage tank fires

API-2021a: Prevention and suppression of fires in large tanks

API-2030: Application of fixed waterspray systems

API-2218: Fireproofing practices in oil refineries

API-2510: Design and construction of LPG installations

API-2510a: Fire protection considerations in LPG installations

Institute of Petroleum

IP-15: Area class'n codes for installations handling flammable fluids

IP-19: Fire precautions at refineries and bulk storage installations

HSE: The storage of flammable liquids in tanks

United States Air Force / US Military

UFC 3-600-01: Fire Protection Engineering for Facilities

UFC 3-600-02: Maintenance of Fire Protection Systems

UFC 4-211-01: Fire Protection for Aircraft hangers: Type I & II

ETL 00-7: Correlation of US and Host Nation Codes

ETL 02-15: Fire Protection for New Aircraft Facilities

ETL 98-2: Fire Protection for Existing Aircraft Facilities

USAF Fire Engineering Aide Memoir 28

USAF Engineering Support Agency (AFSESA)

US Military Standards

Ministry of Defence

MOD Specification 036: Services installations for buildings

MOD PI 16-2004: Specification 036 section 4 amendments

Ministry of Justice

Fire Standards in Prison Establishments

Ministry of Justice Fire Standards

Technical Specification STD/M/SPEC/045

Department of Education

Building Bulleting 100: Design for fire safety in schools

Sprinklers in schools

Department of Health

HTM 05-01: Managing healthcare fire safety

HTM05-02: Fire safety of health care premises

HTM05-03: Fire detection and alarm systems

British Airways Authority

Fire Alarm & Public Address

Mechanical Building Services (inc Sprinklers)

Public Health and Water

Airbus UK ltd

Parameters for Sprinkler & Hydrant systems

London Underground Ltd

2-01023-001: Fire Safety Engineering Principles to LUL Premises

2-01023-002: Design and Installation of Fire Protection Systems

2-01023-003: Active Fire Protection Systems

2-01023-004: Passive Fire Protection Systems

2-01023-005: Maintenance of Fire Protection Systems

Tubelines Ltd

TLL-ENG-S1403-A1:  Fire Safety Strategy

TLL-ENG-S1404-A1:  Fire Fighting Equipment

TLL-ENG-S1405-A1:  Fire Detection

TLL-ENG-S1406-A1:  Fire Suppression

TLL-ENG-S1407-A1:  Fire Compartmentation

UK Maritime Codes

Safety Guide for Navigation, Tank-Barges and Terminals

DOT - Port Marine Safety Code

Crown Fire Standards

Part F: Special risk

Crown Fire Standards: Section B

Crown Fire Standards: Section D

  ASME / ANSI Standards

ASME B1.20.1: Pipe threads
ASME B16.5: Flange fittings
ASME B16.9: Butt weld fittings
ASME B16.10: Valves
ASME B16.11: Sockets-Threaded fittings
ASME B16.20: Metalic gaskets
ASME B16.21: Gaskets
ASME B16.34: Valve types

ASME B16.47: Flanges
ASME B18.2.1: Bolts
ASME B18.2.2: Nuts
ASME B31.1: Piping
ASME B36.10: Seamless piping
ASME B36.19: Stainless steel piping
ASME B36.10: Pipes schedules
ASTM F2164-02 Field Leak Testing of Polyethylene (PE) Pipe

  Approvals

LPCB Red Book Live
FM Approval listings

NFPA UL Listings
Watermist equipment

Legislation & Regulations

  Legislation

Building Safety Act 2022 

Fire Safety Act 2021 

The Building Act 1984

London Building Act 1939

Public Health Act 1961

The Regulatory Reform (Fire Safety) Order 2005

  Regulations

England & Wales Building Regulations

The Fire Safety (England) Regulations 2022

The Furniture and Furnishings (Fire) (Safety) Regulations 1988

The Fire Precautions (Sub-Surface Rail Stations) Regulations 2009

The Merchant Shipping (Fire Protection) Regulations 2003

Building Regs ADB: Volume 1: Dwelling Houses Fire Safety

Building Regs ADB: Volume 2: Non-Dwelling Houses Fire Safety

Building Regs ADB: Volume 2: Insurers requirements

London District Surveyors Association

Fire Safety in Section 20 Buildings

UK Water Authority

Water Supply Regulations 1999

Water Supply Regulations Guidance

Thames Water Fire Fighting Water Supply Connections

Scotland Building Regulations

Section D: Structural Fire Precautions

Section E: Facilities for Fire Fighting

Construction Design & Management

The Construction (Design and Management) Regulations

The Role of the Client

The Role of the Planning Supervisor

The Role of the Designer

The Pre-Tender Health & Safety Plan

The Construction Health & Safety Plan

The Health & Safety File

Highways Regulations

BD 78/99A: Design of Road Tunnels

BD 78/99B: Ventilation

BD 78/99C: Drainage

BD 78/99D: Plant Monitoring and Control

BD 78/99E: Secondary Cladding

Technical Data

  Technical Standards

Components

TS10101 : Wiring diagram - DOL starter- single phase supply

TS10102 : Wiring diagram - DOL starter- 3 ph - phase to phase

TS10103 : Wiring diagram - DOL starter- 3 ph - phase to neutral

Assemblies

TS20001 : Flange bolting

TS20100 : Life safety - Bypass arrangement

TS20101 : Life safety - Bypass arrangement

TS20301 : Alarm valve labelling

TS20401 : Alarm valve labelling - Wet, Alternate & Dry

TS20402 : Alarm valve labelling - Deluge

TS20501 : Valve positioning

TS21001 : Air supply arrangements - Automatic air compressor

TS21002 : Air supply arrangements - Site air supply

TS21003 : Air supply arrangements - Component list

TS21004 : Pressure switch - Air compressor

TS22001 : Initiation/test assembly - Fire pumps

TS22002 : Pressure switch - multiple use

TS22003 : Pressure switch settings

TS22010 : Fire pump suction arrangements

TS22011 : Fire pumps suction condition #1 - Positive head

TS22012 : Fire pumps suction condition #2 - Suction lift

TS22013 : Fire pumps suction condition #3 - Suction lift

TS22014 : Priming - Suction condition #3 - Suction lift

TS22015 : Delivery arrangements - Flanged valves

TS22016 : Delivery arrangements - Wafer valves

TS22100 : Diesel engine pump room heating and ventilation

TS23001 : Initiation/Test arrangement - Pumps On/Off control

TS23002 : Pressure switch - On/Off pump control

TS23003 : Pressure switch - On/Off control

TS23010 : Jockey/Booster pumps suction #1 - Positive head

TS23011 : Jockey/Booster pumps suction #2 - Suction lift

TS23012 : Jockey/Booster pumps suction #3 - Booster pump

TS23013 : Jockey/Booster pumps - Component list

TS23014 : Jockey/Booster pump curve

Fixings

TS30201 : Nuts, Bolts & Studding - Dimensions & Loadings

TS30202 : Anchor fixings - Dimensions & Loadings 

TS31000 : Pipe supports

TS31001 : Pipe supports - terminology

TS31002 : Pipe support locations

TS31003 : Sling rod, eyerod & u-bolt sizing

TS31004 : Steelwork sizing - Un-braced cantilever supports

TS31005 : Steelwork sizing - Braced cantilever supports

TS31006 : Steelwork sizing - Spanned supports

TS31007 : Steelwork sizing - Definitions

TS31008 : Steelwork sizing - Multiple pipeline supports

TS31009 : Steelwork sizing - Multiple pipeline cantilever supports

TS33002 : Pylon - Inline - Spacing & dimensions

TS33004 : Pylon - T junction - Spacing & dimensions

TS33005 : Pylon - Corner - Spacing & dimensions

TS33008 : Pylon - Bracing, corner & fixing plate details

TS33009 : Pylon - Base & gusset plate details

TS33010 : Multiple pipe supports

Systems

TS40101 : Conversion - Metric / Imperial / US

TS40102 : Pipe volumes

TS40103 : Pipe weights

TS48001 : Static thrust

TS48002 : Dynamic thrust

TS48003 : Surge pressure

TS48100 : Venting of sprinkler systems

TS48200 : Flushing of sprinkler systems

Procedures

TS54001 : Pressure testing - pipework

TS54002 : Pressure testing - Acceptable leakage & pressure loss

Protection

TS61001 : Ingress protection

TS61005 : Live electrical equipment clearances

TS62001 : Power supplies - Electrical fire pumps

TS62002 : I2t characteristics - T type fuse link

TS62003 : Comparative fuse link ratings

TS62004 : I2t values - T type fuse links

TS62005 : Characteristics - J type fuse links

TS62006 : Motor duty fuse links - Direct online starting

TS62007 : Motor duty fuse links - Star delta starting

Labels

TS65901 : Pipe identification

TS66000 : Label - Hydraulic data - Roof only BS/LPC

TS66001 : Label - Hydraulic data - Roof & Rack BS/LPC

TS66002 : Label - Hydraulic data - NFPA/FM

TS66003 : Label - Alarm gong

TS66004 : Location plate - External

TS66005 : Location plate - Internal

TS66006 : Label - Equipment

TS66007 : Label - Equipment

TS66008 : Label - Planned preventative maintenance

Schematics

TS70201 : Sprinkler Pump House Electrics

TS70202 : Sprinkler Pump House Wiring Schematic

TS70203 : Sprinkler System Monitoring Schematic

  SystemFax

SF01 : Flanged pipe joints
SF02 : Underground pipework
SF03 : Fire pump initiation
SF04 : Pipe couplings
SF05 : Alarm testing - mechanical
SF06 : Pipe fittings and couplings
SF07 : Malleable iron fittings
SF08 : Butterfly valves
SF09 : Sprinkler pump testing
SF10 : Pre-action sprinklers
SF11 : Commissioning pumps
SF12 : Water bylaws
SF13 : Labels
SF14 : Vibration
SF15 : Static head gain
SF16 : Matthew Hall ALT alarm valves
SF17 : ESFR sprinkler installations
SF18 : Frost protection
SF19 : Pressure switches and gauges
SF20 : Electrical bonding and grooved couplings
SF21 : Fire pumps - duty pressure and total head
SF22 : Approval of cabling material
SF23 : Fire pumps - holding down bolts
SF24 : Air charged systems
SF25 : Pipework feeding single sprinklers
SF26 : Reliable sprinkler valves
SF27 : Tesco design requirements
SF28 : LPS1048 certification
SF29 : LPCB Approved piping
SF30 : Ductile iron pipe and fittings
SF31 : Water bylaws
SF32 : Welded fabrication

SF33 : Victaulic mechanical tees

SF34 : Victaulic mechanical tees
SF35 : Building regulations 2000
SF36 : Pressure gauges
SF37 : False alarms
SF38 : Reliable alarm valve trim
SF39 : Calibrated test pressure gauges
SF40 : Grooved couplings
SF41 : Influx Firesure flowmeters
SF42 : Labels
SF43 : Pre-action systems
SF44 : Pressure switches
SF45 : Electrical conductor colour identification
SF46 : Pipe supports
SF47 : Exhausters on dry/alternate installations
SF48 : Sprinkler identification numbers
SF49 : Intermediate sprinkler calculation
SF50 : Rapidrop Flexible sprinkler connections
SF51 : ANSI / BSI piping schedules
SF52 : LPC Life Safety Requirements
SF53 : Influx Platon Flowmeters
SF54 : British & European standard changes
SF55 : Corrosion in Metals
SF56 : BSEN12845:2003 Signal Requirements
SF57 : LPC Technical Bulletins
SF58 : Electrical Basics
SF59 : Air Receivers
SF60 : Approved Document B Vol.1
SF61 : Sprinkler Systems Maintenance
SF62 : UK Property Usage Classification
SF63 : LPC TB217 & TB234 Storage Restrictions

TTBT01 : Sprinkler pipework bracketry
TTBT02 : Sprinkler flexible drops
 

Guidance and Information

  Guidance Documents

Fire Protection Association
Frost Protection Measures for Sprinklers
Legionella and Fire Fighting Systems
Supply of Water to Fire Sprinkler Systems
Management of Fire Water in Sprinkler Protected Properties
Associations
BAFSA – Information files
WRA - Selection of water supply pipes in contaminated ground
RSA - BS9251-2021 Guidance
BRE - External fire spread: Building separation and cladding
BRE - Concrete structures in fires
CIBSE - Guide E: Fire safety engineering
DIPRA - Design of thrust restraints
RIBA - Plan of work 2020
USNRC - Potential Problems with Heat Collectors

General

FOC 1st Edition 
History of Sprinkler Development

Loss Prevention Certification Board
LPS1014: Fire detection and alarm system
LPS1048: Automatic Sprinkler system
LPS1204: Gas extinguishing systems
LPS1301: Residential and Domestic Sprinkler Systems
LPS Loss Prevention Standards 


LPS1048 / GN01 - Shopping Complexes
LPS1048 / GN02 - FHC Control Procedures
LPS1048 / GN03 - Completion of Certificates
LPS1048 / GN04 - Issue of Certificates
LPS1048 / GN05 - Restriction Categories
LPS1048 / GN10 - Control of Departures
LPS1048 / GN11 - Quality Requirements
LPS1048 / GN12 - Service and Maintenance
LPS1048 / GN13 - Competency Requirements